Operating modes
Selector without access code Selector with access code
Mono-directional.
Key 1
CODE ► key 1
Mono-directional opposite side.
(flashing LED).
Key 1
CODE ► key 1
Bi-directional.
Key 2
CODE ► key 2
Partial opening.
(Only for mono-directional and bi-directional).
NOTE: if the automation has 2 swinging wings, it
allows 1 wing opening only.
Key 3
CODE ► key 3
Sliding door open.
Key 4
CODE ► key 4
Swing door open.
Key 4
CODE ► key 4
Delayed night locking (STOP).
Start the sequence: bi-directional (10 s with J1=ON; 60
s with J1=OFF) ► door closed (max 60 s) ► STOP.
Key 5
CODE ► key 5
Immediate night locking (STOP).
Key 5
CODE ► key 5
Sliding door closed.
Key 6
CODE ► key 6
Swing door closed.
Key 6
CODE ► key 6
Opening command.
Key + any key
Key + CODE
POWER RESET.
Deletes all data learned by the control panel.
Key 1
+ key 5
CODE ► key 1
+ key 5
Code setting (J3=ON).
NOTE: the code has a maximum of 5 digits.
During the setting operation the red led flashes.
Key
► CODE ► key
Code erasing (J3=ON)
NOTE: during the erasing operation the red led flashes.
Key