EasyManua.ls Logo

Epson AcuLaser C1100 - Page 166

Epson AcuLaser C1100
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON AcuLaser C1100 Revision B
TROUBLESHOOTING FIP according to the printer message 166
11
Operation check of SENSOR REGI
The voltage of P408-12P408-11 on
PWBA MCU is 0 VDC when ACTUATOR
REGI enters the sensor sensing area, and is 5
VDC when it leaves the sensing area?
Go to Step [17]. Go to Step [12].
12
5 VDC power supply check to SENSOR REGI
The voltage of P408-10P408-11 on
PWBA MCU is 5 VDC?
Go to Step [13]. Go to Step [15].
13
Continuity check of HARNESS-ASSY P/H1
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-10J603-3
J408-11J603-2
J408-12J603-1
Go to Step [14]. Replace
HARNESS-
ASSY P/H1.
14
Continuity check of HARNESS-ASSY P/H2
Disconnect P/J603 and P/J102 from PWBA
MCU.
Do all of the wiring below have normal
continuity?
P603-10J102-3
P603-11J102-2
P603-12J102-1
Replace
SENSOR
REGI. (p.336)
Replace
HARNESS-
ASSY P/H2.
15
5 VDC power supply check to PWBA MCU
The voltage of P410-3P410-4 on PWBA
MCU is 5 VDC?
Replace PWBA
MCU. (p.404)
Go to Step [16].
16
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-3J502-3
J410-4J502-4
Replace LV/
HVPS. (p.407)
Repair broken
or shorted part.
Step Check Yes No
17
24 VDC power supply check to P/H MOTOR
The voltage of P409-6P409-5 on PWBA
MCU is 24 VDC?
Go to Step [18]. Go to Step [20].
18
Continuity check of HARNESS-ASSY P/H1
Disconnect the P/J409 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J409-1P604-6
J409-2P604-5
J409-3P604-4
J409-4P604-3
J409-5P604-2
J409-6P604-1
Go to Step [19]. Replace
HARNESS-
ASSY P/H1.
19
Check after replacement of MOTOR-PH
Replace MOTOR-PH. (p.337)
Does the error recur when a test print is made?
Replace PWBA
MCU. (p.404)
End of
procedure
20
24 VDC power supply check to PWBA MCU
The voltage of P410-5/6 P410-7/8 on
PWBA MCU is 24 VDC?
Replace PWBA
MCU. (p.404)
Go to Step [21].
21
Continuity check of HARNESS ASSY MAIN
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-5J502-5
J410-6J502-6
J410-7J502-7
J410-8J502-8
Replace LV/
HVPS. (p.407)
Repair broken
or shorted part.
22
Continuity check of HARNESS-ASSY P/H1
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-1J603-12
J408-2J603-11
Go to Step [23]. Replace
HARNESS-
ASSY P/H1.
Step Check Yes No

Table of Contents

Other manuals for Epson AcuLaser C1100

Related product manuals