EPSON AcuLaser C1100 Revision B
DISASSEMBLY AND ASSEMBLY TRANSFER 349
REINSTALLATION
1. Insert the left-side gear on 2ND BTR ASSY into the main unit, and then fit the left
and right bearings on 2ND BTR ASSY into FRAME ASSY-2ND to attach 2ND
BTR ASSY.
2. Turn the levers on both the left and right sides of 2ND BTR ASSY down, and
make FRAME ASSY-2ND lock the lever.
3. Attach Photoconductor Unit.
4. Close COVER ASSY TOP.
C A U T I O N
When performing the following work, press LATCH
ROTARY on LATCH ASSY ROTARY to release the latch,
turn FRAME ASSY-ROTARY by hand, and move
HOUSING ASSY-DEVE to prevent it from contacting MAG
ROLL.
When performing the following work, the right-side shaft on
2ND BTR ASSY must be inserted into the bottom side of the
terminal on PLATE BIAS-2ND ASSY.
C A U T I O N
After attaching 2ND BTR ASSY, make sure that the levers on both
the left and right sides move smoothly up and down.
C A U T I O N
When replaced 2ND BTR ASSY with a new one, clear the life
counter to zero. (Refer to “6.3.1 Maintenance Menu Items” (p497))