1 - 162
Chapter 1 Troubleshooting
Epson AcuLaser C2900N
Revision B
Confidential
5
Checking the DRUM CARTRIDGE for connection.
Remove the DRUM CARTRIDGE.
Are five HV terminals on the DRUM CARTRIDGE, and five
springs on the frame (PL4.1.10 and PL4.1.15 to 18) dirty
and/or deformed?
Clean and/or
replace the DRUM
CARTRIDGE or
SPRING(s).
Go to step 6.
6
Checking after resetting the DRUM CARTRIDGE.
Reseat the DRUM CARTRIDGE.
Is the image printed correctly?
End of work. Go to step 7.
7
Checking after replacing the DRUM CARTRIDGE.
Replace the DRUM CARTRIDGE. (Refer to RRP4.6.)
Is the image printed correctly?
End of work.
Replace the
DISPENSER
ASSY. (Refer to
RRP5.1.)
Step Check
Remedy
Yes No