Upper Cover + Control Panel
1. Remove four Screws [1].
[1]
2. Remove the Ground terminal [2].
3. Remove the Connector [3], then remove the Upper Cover [4].
4. Remove five Screws [5], then remove the Control Panel [6].
Be careful when removing the Ground terminal because the edge of the Faston
terminal is sharp. Make sure to work with gloves on to avoid getting injured.