EPSON AcuLaser C9200N Revision D
DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 296
Confidential
8. Remove the C-ring [15] and bushing [16].
9. Remove the C-ring [18] and gear [19] while sliding out the shaft assy [17] in the direction
indicated in the figure above.
4067F2C505DA
10.Remove the C-ring [20] and bushing [21], and remove the shaft assy [22].
11.Remove two E-rings [23] and bushing [24], and remove the pickup roller fixing plate assy
[25].
12.Remove the C-ring [26] and Pickup Roller [27].
A D J U S T M E N T
R E Q U I R E D
When installing the Pickup Roller with a new one, make sure to reset the life counter.
(Refer to Chapter 5 “ADJUSTMENT”) (p313))