EPSON AcuLaser CX11/CX11F Revision B
DISASSEMBLY AND ASSEMBLY Scanner Section 483
6. Turn the Scanner back to normal orientation, and remove the IR COVER A ASSY
from the IR BASE A ASSY. There are two hooks on left and right shorter sides of
the IR BASE A ASSY to secure the IR COVER A ASSY, so push the shorter side
of the IR BASE A ASSY while pulling the IR COVER A ASSY upward to
remove it (do the procedure for both left and right side one by one).
7. Remove a piece of tape that bundles the harness and FFC of the IR COVER A ASSY.
8. Pull out the IR COVER A ASSY harness through the hole on the IR BASE A ASSY.
Figure 4-157. Removal of IR COVER A ASSY (3)
Figure 4-158. Removal of IR COVER A ASSY (4)
C H E C K
P O I N T
The two hooks of the IR BASE A ASSY that secure the IR
COVER A ASSY are indicated on the picture below.
If the IR ENGINE LOCK ASSY and the ADF IR LOCK ASSY
prevent the IR COVER A ASSY from separating from the IR
BASE A ASSY, access them from the bottom of the IR BASE A
ASSY to set them in position so that they do not interfere the IR
COVER A ASSY.
Hooks
IR BASE A ASSY
IR ENGINE LOCK ASSY
ADF IR LOCK ASSY
Bottom of the IR BASE A ASSY
IR COVER A ASSYIR BASE A ASSY
6)
8)
IR COVER A ASSY
IR ENGINE LOCK ASSY
ADF IR LOCK ASSY
Through-hole for the Harness
Harness