DISASSEMBLY/ASSEMBLY Disassembly Procedures 125
Confidential
8. Disconnect the Panel FFC from the connector of the Panel Unit. (See Fig.
4-40.)
9. Remove the screw (x1) that secures the Panel Unit and remove the Panel Unit
from the Upper Housing.
Figure 4-40. Removing the Panel Unit (2)
Align and insert the dowel of the Right Hinge to the positioning
hole of the Panel Unit. (See
Fig. 4-40.)
Insert the rib A of the Ratchet Holder Assy to the position
shown in
Fig. 4-38.
A D J U S T M E N T
R E Q U I R E D
After removing/replacing the Panel Unit, make the specified
adjustments. (See
Chapter 5 "ADJUSTMENT".)
Positioning hole & dowel
C.B.P. 3x10 (6±1Kgfcm)
Panel Unit
Panel FFC