3. Determine the position of the wall plates mounting holes.
Use at least three mounting holes.
If you are securing the wall plate in four places, drill the holes indicated by A or B in the illustration
below.
If you are securing the wall plate in three places, drill the holes indicated by C in the illustration
below.
Steps 4 to 8 below provide instructions for attaching the wall plate to a concrete wall.
4. Drill holes of the following diameters and depths.
5. Remove the template sheet.
6. Use a device such as a dust pump to clean out concrete dust from the hole.
7. Position the wall plate on the wall and insert M10 × 60 mm expansion anchors into the holes. Attach
the nut and tap it with a hammer until the core touches the top of the anchor.
Drill diameter 0.41 in. (10.5 mm)
Pilot hole depth 1.8 in. (45 mm)
Anchor hole depth 1.6 in. (40 mm)
Four mounting holes
Three mounting holes