Category Item Status Display Explanation
Status Information Source HDMI Displays the source name for the connected equipment currently being projected.
HDBaseT
DVI-D
SDI
Computer
BNC
LAN
On-Screen Display On Displays the settings for the On-Screen Display. When set to Off, the menus or messages are
not displayed on the projected images.
Off
A/V Mute On Displays the operating status of A/V mute.
Off
Air Temp - Displays the usage environment temperature.
Temp Level -
AC Voltage - Monitors the status of the input voltage, and displays a warning or an error when a momentary
voltage drop occurs.
The 10 most recent logs are displayed in Voltage Warning Info from the Info menu.
When you select Detail when a Warning or Error is displayed, you can check detailed logs for
before and after the error was detected.
Example:
175V: Indicates that the voltage is 175V.
B50V: Indicates that the voltage is 50V or less.
---V: Indicates that there are no voltage logs available.
Check the following if logs are not displayed correctly.
s "Detailed logs and error message are not displayed" p.203
<Warning1> Voltage drop: If the input voltage drops below 89 V for more than 1,000 msec, logs for
approximately one second* before and after the event (120 logs) are displayed.
* The number of seconds varies according to the power supply frequency (50 Hz/60 Hz).