Category Item Status Display Explanation
<Warning2> Power flicker: If the input voltage drops below 85 V for more than 40 msec, and the voltage
returns within 60 msec, logs for approximately one second before the power flicker was detected
(60 logs) and for approximately 0.1 seconds after (6 logs) are displayed.
<Error> Power cut: If the input voltage drops below 85 V for more than 60 msec, the projector is
automatically disconnected from the power supply. Logs for approximately one second before
the event was detected (60 logs) are displayed.
When direct shutdown is enabled, an <Error> is generated when a direct shutdown is
performed, however this is not an actual error.
Laser Status On Displays the operating status of the light source.
Off
Source Source HDMI Displays the source name for the connected equipment currently being projected.
HDBaseT
DVI-D
SDI
Computer
BNC
LAN
Resolution - Displays the resolution of the current input signal.
No Signal: No signals are being input.
Not Supported: The projector does not support the current input signal.
Reading the Status Display