5-4
EMP-S4
SEIKO EPSON Revision:B
5.1.3 Software DIP Switches
Some software DIP-switch settings are only accessible from the AS menu. To display the DIP-
SW Setting Menu, do the following operation.
1. Press Menu button on the remote control for at least 5 seconds.
2. Within 4 seconds after releasing the Menu button, hit these buttons in order shown below.
Esc Esc Tele Wide
The following sub-menu is displayed.
Switch On or Off, as necessary
DIP-SW
No
BIT Function
Default
Setting
Setting Value Note
SW1 0 (reserved) - - -
1 Select USB key code 1
0: , ,
1: PageUp,
PageDown
-
2 (reserved) - - -
3 (reserved) - - -
4 (reserved) - - -
5 (reserved) - - -
6
Volume gauge display
ON/OFF
1 0: OFF, 1: ON -
7 (reserved) - - -