4-33
EMP-S4
SEIKO EPSON Revision:B
4.2.19 Removing the Power Supply Fan B and Power Supply Assy
1. Remove the two (C.P.(S-P2)SCREW, 3x20, F/ZN-3C) screws that secure the Power Supply
Fan B, and remove the Power Supply Fan B from the Power Supply Assy.
Figure 4-37.
2. Remove the heat-resistant tape that secures the Power Supply Cable.
3. Remove the 4 (C.B.P-TITE, 3x10, F/ZB-3C) screws that secure the Power Supply Assy and
remove the Power Supply Assy. Extra caution is required as one of the screws is located
underneath the Insulation Plate Ballast.
Figure 4-38.
Power Supply Fan, B
Power Supply Assy.
Isulation
Plate Ballast