4-35
EMP-822/EMP-83/EMP-X5/EMP-S5
SEIKO EPSON Revision:A
4.4.3 Removing the Lamp Lid Detection Switch/TH Board Assy.
Removing the Lamp Lid Detection Switch
1). Remove the screw (C.P.P-TITESCREW,2.5X8,F/ZN-3C) that secures the Lamp Lid
Detection Switch, and remove the Lamp Lid Detection Switch.
Removing the TH Board Assy.
1). Remove the screw (C.B.P-TITE SCREW,3X10,F/ZB-3C) that secures the TH Board
Assy., and remove the TH Board Assy.
Figure 4-31.
This part is designated as the Safety Device. When removing/replacing the part
for repair, be sure to refer to the following section. According to the instructions
in it, handle the part and perform the procedure after servicing.
4.1.4 "Safety Check after Servicing" (p. 4)