LQ-300 Service Manual
Disassembly and Assembly
3.2.4.9 Removing the PG Sensor
1.
Remove the printer mechanism (see Section 3.2.4).
2. Release the 2 clips attaching the PG sensor and remove it. The clips can be accessed through 2
holes in the left frame; to release the clips, push each with a pair of tweezers.
/
PG
/
Left Frame
Sensor
Figure 3-18. Removing the PG Sensor