REV.-A
DISASSEMBLY, ASSEMBLY, AND ADJUSTMENT
Table 4-6. LQ Mode
Control
Value
DIP SW
1-5 1-6 1-7 1-6
Direction and Value of Shift
-7 ON ON ON ON
-6 ON ON ON
OFF
-5 ON ON
OFF ON
-4
ON ON
OFF
OFF
-3
ON
OFF ON ON
-2
ON
OFF ON
OFF
-1
ON
OFF
OFF ON
0
ON
OFF OFF
OFF
7/720 inch
6/720
inch
5/720 inch
4/720 inch
3
/720 inch
2/720
inch
1/720
inch
Normal position
m
I
*---a
Printing starts n/720 inch to
the left of the reference
position.
,,
I
4
4
Printing starts here
(reference position).
+1
+2
+3
+4
+5
+6
+7
OFF
OFF
OFF ON
OFF
OFF ON
OFF
OFF
OFF ON ON
OFF ON
OFF OFF
OFF ON OFF ON
OFF ON ON
OFF
OFF ON ON ON
1/720
inch
2/720 inch
3/720
inch
4/720
inch
5
/720 inch
6/720
inch
7/720
inch
,--m-e‘)
I
4
Printing starts n/720 inch to
the right of the reference
position.
NOTE:
If all DIP switches are OFF, the control values will be set to the provisional test values.
4.3.4.2 Adjustment Procedures
Because the adjustment mode is incorporated into the unit, the following adjustment procedure requires no
special equipment. All that is required is paper. The adjustment procedure is outlined in Figure 4-42. Note
that the adjustment must be carried out twice -
once for Draft mode (120 dpi) and once for LQ mode (360 dpi).
4-30
LQ-510