EPSON Perfection V500 Photo Revision A
OPERATING PRINCIPLES Operation Principle of Electric Circuit 23
2.3 Operation Principle of Electric Circuit
The following electric circuits are used in the scanner.
Main Board
CCD Board
Panel Board
This board has four buttons (Start/Copy/Scan to E-mail/Scan to PDF) and LED
lamp.
Power supply
The scanner is powered with 24 VDC voltage from the AC adapter.
AC adapter rated voltage
• Rated output DC24V 1.3A
• Input Voltage AC100-120V ± 15% (100V)
AC220-240V ± 15% (200V)
• Rated Input Current 1.0A (AC 100V system)
0.5A (AC 200V system)
• Input Frequency Range 50 to 60Hz ± 0.3Hz
• Output Voltage DC24 to 26.4V
The 24 VDC voltage is supplied to CN4 on the Main Board. A power switch is located
between the DC jack and the Main Board.
DRV Board (TPU Unit)
Table 2-1. Main Board IC
Name Location Details
S1R77002B00A000 IC4 ASIC: Host base scanner controller
S1R720G0F00A0 IC6 ASIC: UTM (USB2.0 interface)
EM636165TS-7G IC3 SDRAM 1M x16bit x4bank
TB62205FG IC1
Motor Driver + DC-DC converter CR Motor Drive
+24V IN, +12V/+3.3V OUT
AP1120SLA IC2
DC-DC converter
+5V IN, +3.3V/+2.5V OUT
M74HC595AM13TR IC5 Serial-Parallel converter
Table 2-2. CCD Board IC
Name Location Details
ILX562K P1 CCD
SN74ACT244NSR IC1, IC2 CCD drive buffer
KIA78M12F-RTF/P IC5
DC-DC converter
+14.24V IN, +12V OUT
Table 2-3. DRV Board IC
Name Location Details
M74HC595RM13TR IC1, IC2 8bit Shift Register
LB11847L-E IC3 TPU CR Motor Driver
CD74HC75M96 IC5 LED controller