EPSON Perfection V500 Photo Revision A
DISASSEMBLY / ASSEMBLY Disassembly Procedure 44
4.2.11 Removing the Sensor Board
1. Remove the TPU Lower Housing. See Section 4.2.10 on page 43.
2. Remove the C.B.P. M3 x 8 screw that secures the Sensor Board.
3. Disconnect the Sensor Connector CN1 while lifting the Sensor Board, and remove
the Sensor Board.
Figure 4-31. Removing the Sensor Board
4.2.12 Removing the Hinge Assy.
1. Remove the TPU Lower Housing. See Section 4.2.10 on page 43.
2. Remove the four C.B.P. M4 x 12 screws that secure the left and right Hinge Assy.s
and remove them.
Figure 4-32. Removing the Hinge Assy.
Sensor Board
C.B.P. 3 x 8
(6.5±0.5kgf.cm)
CN1
C.B.P. 4 x 12
(6.5±0.5kgf.cm)