13 Rev.7.4
8.Error Message
Table of Error Messages
Message Content Cause
Confirm connection
Check USB connection
SG-WRITERII is not connected USB cable is not connected
Check USB cable
SG-WRITERII is not connected USB cable is not connected
Version error
HW/Firm Version Error
Improper version Wrong Hardware & Software versions
DLL Version error Improper DLL version Wrong software version
No answer No calculation results or analysis Unwritable frequency
Current Error
Short Check error
Power is improperly flowing to
device. (“Check Direction!” is
displayed in message box.)
Direction of devices is backward
Device is defective
SG-WRITERII is defective
Pin Error Pins are not making contact
Device is defective
Defective device connection
Device is not SG8002/SG8003
Blank Error Device already written
Device is defective
Defective device connection
Device is not SG8002/SG8003
Reference Error Quartz frequency is out of
appropriate range
Packages are different
Device is defective
Defective device connection
Device is not SG8002/SG8003
Device Error Device has other errors Same as above
Verify Error Inconsistent Write Data and Read
Data
Device is defective
Defective device connection
Fout Error Output frequency is outside of
designated Rank
Trimming defect when writing
Defective device connection
IDD Error Exceeds standard value for power
consumption
Device is defective
Calibration of current measuring section
necessary
OE Error OE function is defective
Device is defective
Defective device connection
Calibration of current measuring section
necessary
Vrange Error VDD(min) / VDD(max) error
Device is defective