Main Controller (C172 MAIN Board) Removal
1. Remove the upper housing. (See page 3-7.)
2. Remove the printer mechanism. (See page 3-9.)
3. Remove the cables from connectors CN4 and CN16 between the power supply unit and the
C172 MAIN board and the cable from control panel connector CN3.
4.
Remove 2 (CBS 3 × 12) screws securing the upper connector cover and the Type B interface
shield cover to the lower housing. Then remove the upper connector cover.
5.
Remove 7 (CBP 3 × 12) screws and 2 (CBS 3 × 6) screws securing the C172 MAIN board to the
lower housing. Then remove the controller board along with the shield cover.
6.
Remove 2 (CP 3 × 6) screws securing the shield cover to the C172 MAIN board, and remove
the shield cover.
REQUIRED ADJUSTMENTS
When you replace the main board, initialize EEPROM contents as follows:
1. Reassemble the printer.
2. Turn the printer on while holding down the Alt, LF/FF, Economy / Condensed, and
Pause buttons on the control panel.
When the EEPROM is initialized, some default settings (for example, the Bi-D setting,
head gap / angle / black-color head gap, head drive voltage settings, etc.) are lost. So,
you need to adjust the printer. (See Chapter 4.)
When the EEPROM is initialized, the protect counter is also reset; so you need to replace
the ink drain pad. (See pages 2-29 and 3-20.)
CAUTION
The C172 MAIN board shield plate has sharp edges, so take care handling it.
Take care handling the lithium battery, as described on page 3-3.
Replace the control panel harness, and then remove the main controller .
Disassembly and Assembly
3-10 EPSON Stylus 1500 Service Manual