EasyManua.ls Logo

Epson Stylus CX4905 - Page 183

Epson Stylus CX4905
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus CX4900/CX4905/CX5000/DX5000/DX5050/CX5900/CX6000/DX6000/DX6050 Revision A
ADJUSTMENT Adjustment Except Adjustment Program 183
9. Accede to following steps until you’ve completed the left side PG adjustment.
Figure 5-17. Left Side PG Adjustment
10. Tighten the screw for securing Parallel Adjustment Lever (Left) temporary.
C A U T I O N
If you push the Carriage Unit directly, it’s possible to damage
the Print Head surface by the friction with the thickness gauge.
Fol
lowing is the relationship between “Parallel Adjustment
Lever (Left) operation” and “Platen gap reaction”.
Figure 5-16. Relationship between Parallel Adjustment Lever (Left)
Operation & Platen Gap
PG up (narrower)
PG down (wider)
START
Move the Carriage Unit by
using the Timing Belt.
Thickness
Gauge moves?
One notch up the Parallel
Adjustment Lever (Left).
One notch down the Parallel
Adjustment Lever (Left).
Move the Carriage Unit by
using the Timing Belt.
Thickness Gauge
moves?
Advance to Step 10.
Step 8
Yes
Yes
No
No
Note : “Down” means PG
(Platen Gap) wide.
Note : “Up” means PG (Platen Gap) narrow.