EPSON Stylus Photo 925 Revision A
Disassembly and Assembly Disassembly 109
6. Remove the two screws (C.P. SCREW, 3x4, F/ZN) securing the PF Motor, and
remove the PF Motor.
Figure 4-75. Removing the PF motor
T When installing the PF Motor Connector Cable in the Cable
Holder on the ASF Unit, place the cable as shown below.
Figure 4-76. Placing the PF Motor Connector Cable
C.P. SCREW, 3x4, F/ZN
PF Motor Connector Cable
T Install the PF Scale on the PF Roller Gear properly by referring
to 4.2.18.1 “PF Scale installation”.
T Plug the PF Motor Connector Cable in the connector (CN13) on
the Main Board securely.
T Tightening torque for screws
One screw securing the PF Encoder:
C.B.P. SCREW, 2.5x5, F/ZN : 2 ~ 4kgf.cm
Two screws securing the PF Motor:
C.P. SCREW, 3x4, F/ZN : 5 ~ 7kgf.cm
A D J U S T M E N T
R E Q U I R E D
T Once the combination gear 13.6, 33 has been removed from the
Main Frame, be sure to apply an appropriate amount of grease
G-26 to the specified points. (Refer to Figure 6-10. “Lubrication
point 9” in Chapter 6.)