Maintenance Overview 140
Table 6-2.Lubrication Point
NO. Lubrication Type/Point Remarks
1 <Lubrication Point>
Part of the Driven Pulley Holder which comes in
contact with the main frame
See Figure 6-2. "Lubrication point 1".
<Lubrication Type>
•G-26
<Lubrication Amount>
φ1mm x 1mm x 4 points
Apply with a
dropping pipet.
2 <Lubrication Point>
Inside the bore of the CR shaft of the CR Unit
See Figure 6-3. "Lubrication point 2".
<Lubrication Type>
•G-56
<Lubrication Amount>
Apply 12.5 ~ 37.5 mg of lubricant to 8 points.
Lubricate with a
dropping pipet.
Do not attach the
grease to any other
portion of the CR
unit.
While turning the CR
Guide Shaft, apply
grease to every part of
the peripheral surface
of the CR Guide
Shaft.
After lubrication,
make sure that the CR
unit smoothly.
3 <Lubrication Point>
Part of the ASF Hopper which comes in contact with the
cam of the LD Roller (left side)
See Figure 6-4. "Lubrication point 3".
<Lubrication Type>
•G-26
<Lubrication Amount>
φ1mm x 2mm
Lubricate with a
dropping pipet.
Apply grease
properly to the
surfaces of the ASF
Hopper and LD
Roller Cam which
come in contact with
each other.
4 <Lubrication Point>
Part of the gear (spur gear 35.2) of the clutch mechanism
which come in contact with the LD Holder
See Figure 6-5. "Lubrication point 4".
<Lubrication Type>
•G-26
<Lubrication Amount>
φ1mm x 2 points
Apply grease
properly to the
surfaces of the spur
gear 35.2 and LD
Holder which come in
contact with each
other.
5 <Lubrication Point>
Shaft for spur gear 23.2 on the ASF frame
See Figure 6-6. "Lubrication point 5".
<Lubrication Type>
•G-26
<Lubrication Amount>
φ1mm x 2mm
Lubricate with a
dropping pipet.
6 <Lubrication Point>
Part of the ASF Hopper which come in contact with
the ASF frame
See Figure 6-7. "Lubrication point 6".
<Lubrication Type>
•G-26
<Lubrication Amount>
5mm x 2 points
Lubricate with a
dropping pipet.
After applying grease,
operate the ASF
Hopper so that the
grease is spread to
every part.
7 <Lubrication Point>
Part of the front frame where the CR Unit (CR Slider)
operates
See Figure 6-8. "Lubrication point 7".
<Lubrication Type>
•G-26
<Lubrication Amount>
φ1mm x 200mm
Use the lubrication
tool dedicated for the
front frame.
Apply grease in the
left-to-right direction.
Table 6-2.Lubrication Point (continued)