4.2.6.9 Release Holder Assy
1. Remove the ASF Assy. See Section 4.2.4 on page 83.
2. Release the PE Sensor Connector Cable from the five Tabs on the
Release Holder Assy.
3. Remove the three C.B.S. M3 x 6 screws that secure the Release Holder
Assy.
4. Remove the three lower Tabs of the Release Holder Assy from the Main
Frame with a flat-blade screwdriver, and remove the Release Holder Assy
upwards.
Figure 4-105. Removing the Release Holder Assy
2) C.B.S. 3x6
(8±1 kgf.cm)
1
2
3
PE Sensor Connector CableTabs
Release Holder Assy
Rear side
Upper Tabs
Lower Tabs
Front side
Align the three Upper Tabs on the Release Holder Assy
with the positioning holes on the Main Frame. See Figure
4-105.
Fit the FLAG Release Shaft by the Bushings on the
Release Holder Assy.
Figure 4-106. Reinstalling the Release Holder Assy
Tighten the screws in the order shown in Figure 4-105.
Bushings
FLAG Release Shaft