4.2.8 Removing the Sensors
4.2.8.1 PE Sensor Holder
1. Remove the ASF Assy. See Section 4.2.4 on page 83.
2. Remove the PE Sensor Connector Cable from the five Tabs on the
Release Holder Assy and the two Tabs on the Head Cable Cover.
Figure 4-135. Releasing the Cables
3. Release the Tabs that secure the PE Sensor Holder from the notch on the
Main Frame with a flat-blade screwdriver, and slide upwards and then
remove toward you.
Figure 4-136. Removing the PE Sensor Holder
Tabs
PE Sensor Connector CableTabs
Release Holder Assy.
Head Cable Cover
PE Sensor Holder
Front
Tab
Align the four Tabs and Guide Pin on the PE Sensor Holder
with the positioning holes on the Main Frame correctly so
that there is no gap between the PE Sensor Holder and the
Main Frame.
Figure 4-137. Reinstalling the PE Sensor
Tabs
Guid
Guide pin