EPSON Stylus Photo R1800/R2400 Revision B
Disassembly And Assembly Disassembly 126
4.2.8.3 CR Encoder Sensor Board
1. Remove the Carriage Unit. See Section 4.2.6.4 on page 95.
2. Remove the two C.B.P. M2.6 x 5 screws that secure the CR Encoder
Sensor Board.
3. Disconnect the FFC of PW Sensor and Ink Mark Sensor from the
Connector on the CR Encoder Sensor Board, and remove the CR Encoder
Sensor Board.
Figure 4-140. Removing CR Encoder Sensor Board
4.2.8.4 PF Encoder Sensor Holder
1. Remove the Upper Housing. See Section 4.2.1.4 on page 76.
2. Disconnect the FFC from the PF Encoder Sensor Board.
3. Remove the C.B.S. M3 x 8 screw that secures the PF Encoder Sensor
Holder.
Figure 4-141. Removing the FFC and the Screw that Secures
the PF Encoder Sensor Holder
CR Encoder
Sensor Board
FFC
13) C.B.P. 2.6x5
(3±0.5 kgf.cm)
Connector
PF Encoder Sensor Holder
5) C.B.S. 3x8
(6±1 kgf.cm)
Connector
FFC