EPSON Stylus Photo R1800/R2400 Revision B
Adjustment Adjustment 149
5.2.4.2 Adjusting Method of the Colorimetric Calibration
When color measurement is performed at the same place as the repair work
site, calibration is batch-processed. When color measurement is performed at
a place different from the repair work site, calibration is performed by separate
processes. The following illustrates the overall workflow.
Figure 5-21. Overall Workflow
C H E C K
P O I N T
The Color ID Calibration Chart is designed to be printed in a
completely non-compensated state. Therefore, there is no
need to delete an existing Color ID from EEPROM when
printing out a Calibration Chart.
START
USB ID acquisition
Printing date/time acquisition
Printing of a Calibration Chart
USB ID / printing date/time / nozzle check pattern
Drying of the Calibration Chart
Mail the Calibration Chart
to color measurement site.
Receive the Calibration Chart.
Save the color measurement data to a file.
Mail the color measurement data
file to repair work site.
Confirmation of USB ID / printing date/time
Measure the Calibration Chart.
Input the color measurement
data from file or enter
Write the Color ID to a printer.
End
[Repair work site]
[Repair work site]
Fl
ow o
f
b
a
t
c
h
process
i
ng
Flow of separate process
(repair work site)
Flow of separate process
(color measurement site)
[Color measurement site]
Convert the color values (Lab) to Color ID
from color measurement data.