EPSON Stylus Photo R1800/R2400 Revision B
Stylus Photo R2400 Overview 210
At operation Though paper is fed from the
ASF Assy, it stops near the PE
Sensor Lever.
PE Sensor 1. Check that the Connector cable of the PE Sensor is
securely connected to the PE Sensor and Relay Board
Connector CN2.
1. Connect the Connector cable of the PE
Sensor to the PE Sensor and Relay Board
Connector CN2.
2. Check that the Sensor Holder is mounted to the
Mechanical frame correctly.
2. Install the Sensor Holder correctly.
3. Move the Detection Lever manually as when the paper
passes, and check that the Detection Lever returns to the
original position automatically by the Torsion Spring when
released. Refer to the above photo.
3. Replace the PE Sensor Holder Unit with a
new one.
4. Using a tester, check that the PE Sensor is normal.
⋅ Paper absent : 2.4V or more
⋅ Paper present : 0.4V or less
4. Replace the PE Sensor Holder Unit with a
new one.
Table 8-8. Troubleshooting of Paper Out Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
CN2
PW Sensor Connector
Sensor Holder
Detection Lever
Torsion Spring