EPSON Stylus Photo R1800/R2400 Revision B
Troubleshooting Overview 51
At power-on The power-on sequence is
executed but Fatal error is
displayed.
CR drive
mechanism
1. Check that the Carriage Shaft is lubricated with grease. 1. Wipe the surface of the Carriage Shaft with
a dry, soft cloth, and lubricate the Carriage
Shaft with grease G-71.
Refer to Chapter 6 "Maintenance".
At power-on, the PF Motor
does not operate at all.
PF Motor 1. Check that the Connector Cable of the PF Motor is
connected to the Main Board Connector CN16.
1. Connect the PF Motor connector cable to
the Main Board Connector CN16.
2. Check the PF Motor connector cable for damages. 2. Replace the PF Motor with a new one.
3. Check if the PF Motor operates normally. 3. Replace the PF Motor with a new one.
Table 3-12. Troubleshooting of Fatal Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
Carriage Shaft
CN16 PF Motor