EPSON Stylus Photo R1800/R2400 Revision B
Troubleshooting Overview 54
At power-on While the power-on sequence
is being executed, Fatal error
is displayed.
ASF Motor 1. Check that the Connector cable of the ASF Motor is
connected to the Relay Connector.
1. Connect the Connector cable of the ASF
Motor to the Relay Connector.
2. Using a tester, check the resistance value of the ASF
Motor.
Value of resistance : 7.0 ± 10%
2. If the resistance value is abnormal, replace
the ASF Motor with a new one.
3. Check the ASF Motor connector cable for damages. 3. Replace the ASF Motor with a new one.
Relay
Connector
Cable
(for the ASF
Motor)
1. Check that the Relay Connector Cable is connected to the
Main Board Connector CN19.
1. Connect the Relay Connector Cable to the
Main Board Connector CN19.
2. Check the Relay Connector Cable for damages. 2. Replace the Relay Connector Cable with a
new one.
Table 3-12. Troubleshooting of Fatal Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
Relay Connector
ASF Motor
CN19