EPSON Stylus Photo R320 Revision B
DISASSEMBLY AND ASSEMBLY Disassembly 50
2.3.9 Removing ASF Assy.
External View
Figure 2-21. Removing "ASF Assy." (1)
Parts/Units which should be removed before removing "ASF Assy."
Paper Support Assy./Preview Monitor Unit/Housing, Upper/Housing, Middle/
Main Board Unit
Procedure for Removing
1. Take off the Acetate Tape. Then remove connector cable of "PF Motor" and
"PG Motor" from the hook on "ASF Assy".
2. Remove the screws (Screw, Frame, Main) (x3) which secure connector cable
of "PF Motor" and "PG Motor". Then release the connector cable.
3. Remove the screws (x5) which secure "ASF Assy.". Then, remove "ASF
Assy." to the back of the printer.
ASF Assy. Connector Cable
Screw, Frame, Main (5-7kgf.cm)
3 2 1
C.B.S (P4) 3x8 (8-10kgf•cm)
2
5
Hook
Acetate Tape
Screw, ASF
(4-5kgfcm)
4
C.B.S 3x6 (5-7kgf.cm)
C.B.P 3x8 (5-7kgf.cm)
C.B.S (P4) 3x8 (5-7kgf•cm)
3
4
C.B.P 3x8 (5-7kgf•cm)
C.B.S 3x6 (5-7kgf•cm)
1