EPSON Stylus Photo R800 Revision A
TROUBLESHOOTING Overview 59
At power-on While the power-on
sequence is being executed,
Fatal error is displayed.
APG Sensor 1. Check that the APG Sensor Connector cables are
connected to the APG Sensors and Relay Board
Connectors (CN5 and CN6).
1. Connect the APG Sensor Connector
cables to the APG Sensors and Relay
Board Connectors.
2. Check the APG Sensors for damage. 2. Change the APG Sensors for new ones.
Relay FFC 1. Check that the Relay FFC is connected to the Relay Board
Connector (CN1) and Main Board Connector (CN5).
1. Connect the Relay FFC to the Relay
Board and Main Board Connectors.
2. Check the Relay FFC for damage. 2. Change the Relay FFC Cable for a new
one.
Table 3-14. Phenomenon-Based Fatal Error Check Points
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
CN6
CN5
APG Sensors
Relay Connector
Main Board Connector