EasyManua.ls Logo

Epson Stylus Photo RX700 - Page 137

Epson Stylus Photo RX700
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Photo RX700 Revision B
Adjustment Mechanical Adjustment 137
RevisionB
7. Place the gauge on the Paper Guide Front Assy at its left end. (See Figure 5-7)
8. Move the Carriage Assy over the gauge.
9. Turn each of the Adjustment Bushes to a position where the Printhead comes in
contact with the gauge. (See Figure 5-8)
10. Make the PG adjustment again at the right end.
11. Tighten up the screws securing the right and left Adjustment Bushes.
NOTE: Screw tightening torque: 0.59 ± 0.1 N
·m
Figure 5-7. PG Adjustment (Left Side 1)
Figure 5-8. PG Adjustment (Left Side 2)
C H E C K
P O I N T
Adjust the right and left bushes so that the gauge is in even
contact with the printing face of the Printhead.
Turn the bush for the front side shaft by the same scale as the
bush for the main shaft, as a rule.
Set the gauge at the left end, and
move the carriage over the gauge.
Main
shaft side
Adjust the right and
left Adjustment
Bushes so that the
printing face of the
Printhead comes in
even contact with the
gauge.