EPSON Stylus Photo RX900 Revision A
Disassembly and Assembly Removal of Exterior Parts 81
4.2.1.1 LCD Assy
1.
Remove the Panel Assy. (p.80)
2. Remove the screws (x2), and remove the LCD Assy.
3. Remove the LCD Shafts A and B.
4.2.1.2 Disassembly of LCD Assy
1.
Remove the Panel Assy. (p.80)
2.
Remove the LCD Assy. (p.81)
3. Remove the screws (x2), and remove the LCD Lower Housing.
4. Remove the screws (x4), and remove the LCD Shield Plate and the LCD Module.
Figure 4-2. Removing the LCD Assy
Figure 4-3. Disassembling the LCD Assy
C A U T I O N
Take care not to bend the Panel Ground Plate on the back side
when performing disassembly and assembly with the Panel
Ground Plate installed.
C A U T I O N
Take care that the surface of the removed LCD is kept free from
scratches or dust and dirt.
Install the LCD Module so that it is exactly horizontal, and route
the lead wires properly in the LCD Upper Housing.
Torque: 0.6 ± 0.1Nm
C.B.P-Tite 3x8 F/ZN-3C (x2)
LCD Assy
LCD Shaft A
LCD Shaft B
Coil Spring Clutch
Torque: 0.15 ± 0.05Nm
C.B.P-Tite 2x8 F/ZN-3C (x6)
LCD Cover
LCD Module
LCD Lower Housing
LCD Upper Housing
Hooks (x2)
LCD Shield Plate