EPSON Stylus Photo RX900 Revision A
Disassembly and Assembly Removal of Exterior Parts 82
4.2.1.3 Disassembly of Panel Assy
1.
Remove the Panel Assy. (p.80)
2. Remove the screws (x6), and remove the Panel Shield Plate together with the Panel
Ground Plate.
3. Remove the screws (x2), and remove the Panel Board, Light Conduction Tubes, Right
Button and Left Button.
Figure 4-4. Disassembling the Panel Assy
C A U T I O N
Take care not to scratch the surface of the LCD Panel when
performing disassembly and assembly with the LCD Assy
installed.
Make sure that the Panel Board are engaged with the hooks
(three) of the panel housing.
When installing the Panel Ground Plate, make sure that its
projection is fitted into the hole in the Panel Shield Plate.
Panel Ground Plate
Panel Ground Plate
Hooks (three)
Torque: 0.6 ± 0.1Nm
Panel Shield Plate
Panel Board
Panel Ground Plate
Torque: 0.6 ± 0.1N
m
C.B.P-Tite 3x8 F/ZN-3C (x2)
Right Button
Left Button
Light Conduction
Tubes
C.B.P-Tite 3x8 F/ZN-3C (x6)