EasyManua.ls Logo

Epson Stylus Photo RX700 - Scanner Housing

Epson Stylus Photo RX700
202 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Photo RX900 Revision A
Disassembly and Assembly Disassembly of Scanner Unit 97
4.3.2 Scanner Housing
1.
Remove the Scanner Unit. (p.83)
2. Remove the ASF Cover.
3. Remove the nine screws at the bottom of the Scanner Unit.
3x 8 Ni (x2)
3x10 B (x7)
4. Disengage the right and left hooks (x4) of the Scanner Housing, disengage the hooks
(x2) at the rear with the front side opened slightly, and remove the Scanner Housing.
Figure 4-28. Removing the Scanner Housing
C A U T I O N
Once the Scanner Housing is removed, there is a possibility that
dust and dirt may enter the inside of the scanner body. Perform
disassembly and assembly of the Scanner Unit in an
environment that minimizes intrusion of dust and dirt.
Disassembly and assembly on a clean bench is ideal.
There is a possibility of damaging the right and left shanks of
the ASF Cover when removing the Scanner Housing. To
prevent such damage, remove the ASF Cover beforehand.
Perform disassembly and assembly with care not to damage the
document table (glass). In addition, never forget that a very
troublesome cleaning is required if dirt sticks to the inside of
the document table.
Tighten the screws in the order shown below to secure the Scanner
Housing. (Torque : 0.54 ± 0.05 Nm)
3x10 B(x7)
3x8 Ni
3x8 Ni
A D J U S T M E N T
R E Q U I R E D
When the Scanner Housing is removed, make the following
adjustment after reinstallation.
5.4 Scanner Home Position Adjustment (p.142)
Scanner Housing
Hook
x4
ASF Cover
Hooks
Hooks