EPSON Stylus Photo R280/R285/R290 Revision B
Chapter 4 Disassembly/Assembly 4.3.1 Main Board Unit (Removing Control Boards) 63
Disassembling the Main Board Unit
1. Remove the Main Board Unit (p.61).
2. Remove the seven screws and remove the Upper Shield Plate M/B.
• Screw (6 pcs.): C.B.S. M3x6 (tightening torque: 5-7 kgf.cm) (No.1)
• Screw (1 pc.): C.P. M3x6 (tightening torque: 4-6 kgf.cm) (No.7)
(The numbers shown in the figure indicate the order of tightening the screws.)
Figure 4-21. Removing the Upper Shield Plate M/B
3. Remove the two screws and remove the Shield Plate M/B Sub.
• Screw (2 pcs.): C.B.S. M3x6 (tightening torque: 4-6 kgf.cm) (No.1)
(The numbers shown in the figure indicate the order of tightening the screws.)
4. Remove the screw and remove the Main Board Unit.
• Screw C.B.S. M3x10 (tightening torque: 4-6 kgf.cm) (No.2)
Figure 4-22. Removing the Main Board
Do not apply unnecessary force on the screw receiving parts of
the Lower Shield Plate M/B, as they are easy to deform.
When assembling or disassembling the Upper Shield Plate M/B,
be careful of its sharp edges.
Upper Shield Plate
M/B
2
5
1
6
4
7
Lower Shield Plate
M/B
Screw Receiving Part
Be careful of the sharp edges shown in the figure below when
assembling or reassembling.
When installing the Main Board, match the positioning hole
with the guide pin shown in Fig.4-22.
Tighten the screws in the order given in Fig.4-21 (p.63),
Fig.4-22.
Shield Plate
M/B Sub
Upper Side: Main Board
Lower Side: Lower Shield Plate M/B
Sharp edge
Positioning Hole and
Guide Pin