Disassembly & Assembly Disassembly 148
14. Open as inside of the fan duct becomes upward like the rough sketch, after it raises
it a little upward, while paying attention so as not to scar each cable of the right
and left.
Figure 4-73.
15. Disconnect left side suction location detect sensor cable connector.
Figure 4-74.
16. Remove one screw (M4x8) securing the right P_FRONT sensor, and remove
P_FRONT sensor with bracket.
Figure 4-75.
17. Remove the Fan Duct.
Cable right side
Cable left side
Suction location
detect sensor cable
P_FRONT sensor
Screws