EPSON Stylus Pro 10000/10000CF/10600 Revision D
Disassembly & Assembly Disassembly 151
5. Remove two screws (CP(W): M3x6) securing the carriage cover and remove the
carriage cover.
Figure 4-80.
6. Press on the nuts and loosen the nuts on the flexible tubes to remove the metal
pipes in a way that does not loosen the hex head nuts connecting the metal pipes.
Figure 4-81.
C A U T I O N
When loosening the nuts, use some absorbent material to prevent
ink spilling because remaining ink may leak from both metal pipes
and tube sides.
Carriage cover
Screw
(Left side view)
(Right side view)
C A U T I O N
Do not lose the O ring (rubber sealing ring) between the tube and
nut.
If an O-ring is lost, an air leak will occur and ink will not be
supplied.
Figure 4-82.
C A U T I O N
Insert tubes in line with connecting nuts and tighten hex head nuts
with torque wrench (#E589: torque 1kg) to apply proper torque.
Under torque:Ink will not be supplied due to air leak.
Over torque: Ink flow channel will be constricted due to O-
ring deformity and result in ink supply
deficiency and poor starting of normal supply
pump due to incorrect ink supply.
Figure 4-83.
O ring
As the pipe becomes
vertical to the nut it joins.