Disassembly & Assembly Disassembly 183
2. Remove two screws (Mx8) securing Front Cover Sensor R.
Figure 4-165.
3. Disconnect the cable connector CN5 on the C362DRV Board.
4.3.3.27 Removing the I/C Holder Cover Sensor ASSY
1. Remove the R side Cover as described in 4.3.1.4 "R Side Cover Removal".
2. Remove the I/C Holder Cover as described in 4.3.1.6 "I/H Cover ASSY Removal".
3. Disconnect the cable connector from the CN1 on the CSIC Board, then remove
from two clamps.
Figure 4-166.
4. Remove two screws on the I/C Holder Cover sensor, then remove it.
Figure 4-167.
A D J U S T M E N T
R E Q U I R E D
Perform the necessary adjustment listed in Chapter 5. This
adjustment is required to make the Cover Sensor ASSY work
interlocking with the close/open status of the Front Cover.
Screws
C A U T I O N
When removing/replacing, confirm that sensor SW goes on when
cover is closed. (Refer to Self-Diagnosis)