EPSON Stylus Pro 7400/7800/9400/9800 Revision B
Product Description Control Panel 112
Electric
Fatal errors of up to 7 maintenance items recorded as history can be checked. (CPU
error is not recorded.)
Counter display
The counters shown in the table below are displayed. The number is displayed in
hexadecimal.
Serious errors display
Displays error codes of fatal errors. The latest error is 0 and 7 errors are recoreded
in 0 to 6.
Cutting Pressure Adjustment
Adjusts the cutter pressure of the cutter. The pressure can be set in increments of 1%.
Actuator 2
This allows you to check the operation of the Cutter Solenoid, Pump motor, Regulator
Solenoid, and Pressure motor. When you return to the menu screen after the checking
is completed, “Please Turn Off” is displayed on the LCD panel.
Edge Sensor Level Measurement
Measures the platen level (reflecting amount) detected by the paper edge sensor. When
paper is on the rear sensor, the sensor detects the paper width and obtains information
for each paper type. If paper is not on the rear sensor, the sensor obtains information for
each paper type at previous paper width detection.
Panel operations are disabled during executing the measurement. The measured result
is displayed as shown in the table below.
The platen level measurement is conducted from the home side to the anti-home side.
When it is completed, the Carriage moves to the position where the highest level
(reflection) is detected and stops there for three seconds.
Automatic Gap Adjustment
Makes Uni-D and Bi-D (PG 1.6mm/PG 0.8mm) adjustments.
This function automatically prints adjustment patterns in Uni-D and Bi-D, and detects
the highest density point on the printed patterns to automatically reflects the Uni-D and
Bi-D correction values.
The correction value for the Bi-D (PG 0.8 mm) is copied for the Bi-D (PG 1.2 mm) and
the Bi-D (PG 1.6mm) correction value is copied for the Bi-D (PG 2.1mm/PG2.6mm)
Table 1-55. Counter Display Items and Units
Maintenance Unit
Waste ink counter 0.02g
Waste ink counter 2 0.02g
Wiping times Number of times
Rubbing times Number of times
Paper Set Lever releasing frequency Number of times
Front cover opening/closing frequency Number of times
Left and right Ink Lever operating
frequency
Number of times
CR motor reciprocating times Number of times
PF motor travel distance TBD
Number of printed pages Number of print
Cleaning times Number of times
Discharged amount of ink
(A to H columns)
Mega dot
Cutting times Number of times
Cutter Solenoid operating frequency Number of times
No measurement
paper
Minimum
measurement value
Minimum value
detection position
Maximum
measurement value
Maximum value
detection position
Threshold value at
paper detection
Paper presence at
paper detection
Paper absence at
paper detection
D/A value used at
paper detection
OK/NG

Table of Contents