3. Configure the PCU.
2. Set the Temperature to 190.0 (Centigrade). Use the Up and Down Arrows.
1. Turn on the Oven.
3. Press this button to “Lock In” the temperature setting.
4. Turn this Knob to 1.5.
5. Wait for the temperature to reach 190.0 (Centigrade).
Note: It is critical that the Transport Belt is moving while the heater is above 100.0
Centrigrade. Do not turn off the Main Power Switch until the Oven is turned off, and
the temperature drops below 100.0 Centrigrade. When the Main Power Switch is
turned off, the Transport Belt stops moving.