Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908 Revision I
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 335
Confidential
4.4.8.9 Paper Pressing Plate Sensor
1. Remove the Color Measurement Device. (p325)
2. Remove the Mounter. (p327)
3. Remove the three screws that secure the shield plate, and remove the shield plate.
A) Silver, Phillips, Bind machine screw M3x6: three pieces
4. Disengage the hook that secures the Paper Pressing Plate Sensor, and remove the
Paper Pressing Plate Sensor.
5. Disconnect the connector from the Paper Pressing Plate Sensor.
Figure 4-206. Removing the shield Plate
Figure 4-207. Removing the Paper Pressing Plate Sensor
A
Shield Plate
Paper Pressing Plate Sensor
Hook
Connector