Epson Stylus Pro 7700/7710/7700M/7710M/7900/7910/9700/9710/9900/9910/WT7900/WT7910/9890/9908/7890/7908 Revision I
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 340
Confidential
4.4.8.14 Paper Pressing Encoder
1. Remove the Color Measurement Device. (p325)
2. Remove the Mounter. (p327)
3. Remove the three screws that secure the shield plate, and remove the shield plate.
A) Silver, Phillips, Bind machine screw M3x6: three pieces
4. Remove the screw that secures the encoder mounting plate, and remove the
encoder mounting plate.
A) Silver, Phillips, Bind machine screw M3x6: one piece
5. Remove the screw that secures the Paper Pressing Encoder.
B) Silver, Phillips, Bind P-tite M3x8: one piece
Figure 4-214. Removing the shield Plate
Figure 4-215. Removing the encoder mounting plate
C A U T I O N
In the next steps, take care not to damage the scale of the Paper
Pressing Encoder.
A
Shield Plate
B
C
B
C
Encoder mounting plate