Epson Stylus Pro GS6000 Revision F
DISASSEMBLY & ASSEMBLY Disassembly and Assembly Procedure 162
Confidential
4.4.11.2 CAP HEAD
1. Unlock the Carriage and move it to the center. (p83)
2. Remove the MAINTENANCE COVER ASSY (right only). (p91)
3. Press down the right side to disengage the hook beneath.
4. Pull up the left side to detach the CAP HEAD.
Figure 4-135. Releasing the CAP HEAD
5. Pull off the three tubes from the CAP HEAD and remove the head.
Figure 4-136. Removing the CAP HEAD
There are two CAP HEADs, but basically you can remove both of
them in the same way. Therefore this section describes the way to
remove one of them only.
If a tip of the tube is contaminated with ink, make sure to replace it
with a new one. For the procedure, see 4.4.11.3 MAINTENANCE
ASSY Step 4 and 5. (p163)
As seen from the front
Step 2
CAP HEADs
Step 3
Connect the tubes as shown in the figure below.
As this part is moving up and down frequently, make sure to
confirm that the tubes are securely fitted until the end of the
connector to prevent them from dropping with the vibrations.
CAP HEAD
As seen from the front
Tubes