6. Remove the screw on the right, and remove the screw on the left while pushing the
frame to the right as shown below.
A) Silver, Phillips, Cup M3x6: two pieces
7. Remove the MAINTENANCE ASSY drawing out the tubes from the hole
beneath.
Figure 4-139. Removing the MAINTENANCE ASSY
C A U T I O N
If the tip of a tube is contaminated with ink, make sure to replace it
with a new one.
A
MAINTENANCE ASSY
As seen from the top
Make sure to attach the tube (1) for the CAP HEAD (right) to
the one in the rear, and the tube (2) for the CAP HEAD (left) to
the one in the front.
After connecting the tubes, make sure to confirm that the tubes
are securely fitted until the end of the connector to prevent
them from dropping with vibrations.
CAP HEAD (left)
CAP HEAD (right)
[Front]
PUMP ASSY
(front)
PUMP ASSY
(inside)
2
1