DISASSEMBLY/ASSEMBLY Removing the Housing 71
Confidential
4.3.6 Middle Housing
Parts/Components need to be removed in advance:
Scanner Stand/Cover Wire(p 68), Scanner Unit (p 70), Panel Unit (p 72)
Removal procedure
1. Remove the six screws.
Figure 4-15. Removing the Middle Housing (1)
2. Release the two hooks on the left, two hooks on the right, and the hook on the
rear (see
Fig.4-15), then remove the Middle Housing from the Lower Housing.
Figure 4-16. Removing the Middle Housing (2)
Lower Housing
Middle Housing
Rear Side
Hook
SCREW M3x10 P-TITE (5±0.5kgfcm)
When installing the Middle Housing, first align the hook A on the
front left, and then attach the housing. (See
Fig.4-16.)
Left Side
Hook A
Hook
Right Side
Hook