EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
49
11. Open as inside of the fan duct becomes upward like the rough sketch, after it raises it a
little upward, while paying attention so as not to scar each cable of the right and left.
Figure 4-76.
12. Disconnect left side suction location detect sensor cable connector.
Figure 4-77.
13. Remove one screw (M4x8) fixing right P_FRONT sensor, and remove P_FRONT
sensor with bracket.
Figure 4-78.
14. Remove the Fan Duct.
Cable right side