EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
63
4.2.3.8 Removing the CR Motor / Pulley ASSY
1. Remove the R Side Cover as described in R Side Cover Removal 124.
2. Remove the L Side Cover as described in L Side Cover Removal 124.
3. Remove the cable connector of the CR Motor (Lock type).
Figure 4-112.
4. Loosen the CR Tension shaft on the right side of the printer to release the tension on
the CR Steel belt. (Loose two screws with same amount.)
Figure 4-113.
5. Loosen the set screw on the shaft clamp.
Figure 4-114.
C H E C K
P O I N T
Before loosening the CR timing belt tension, confirm and write down
the current tension. See
CR Timing Belt Tension Adjustment for
information on confirming the tension.
Connector
Screw
Pullry
CR steel belt
Set screw
Shaft clamp

Table of Contents