EPSON Stylus Pro 10000/10000CF Revision A
Disassembly & assembly Disassembly Flow
1
84
2. Remove two screws (Mx8) securing Front Cover Sensor R.
Figure 4-169.
3. Disconnect the cable connector CN5 on the C362DRV board.
4.2.3.25 Removing the I/C Holder Cover Sensor ASSY
1. Remove the R side Cover as described in R Side Cover Removal 124.
2. Remove the I/C Holder Cover as described in I/C Holder Cover Removal 125.
3. Disconnect the cable connector from the CN1 on the CSIC board, then remove from
two clamps.
Figure 4-170.
4. Remove two screws on the I/C holder cover sensor, then remove it.
Figure 4-171.
A D J U S T M E N T
R E Q U I R E D
Perform the necessary adjustment listed in Chapter 5. This
adjustment is required to make the Cover Sensor ASSY work
interlocking with the close/open status of the Front Cover.
Screw
Clump
CSIC board
CN1
I/C holder cover sensor
Screw
I/C holder cover sensor